    Fiber optic distribution box, max capacity 24 Splitter, 24 Splices, Box Size
    250*340*110 mm Installation Size 155*180 mm


    SuperDescuento

    GFS-24E

    Fiber optic distribution box, max capacity 24 Splitter, 24 Splices, Box Size 250*340*110 mm Installation Size 155*180 mm

    The equipment is used as a termination point between the power cable and bypass cable to connect to in the FTTH communication network system.
    The fiber splice, the division, the distribution, can be made from this box, and at the same time it provides a solid protection and management for the construction of FTTx networks
    Preferably for installation on the wall.
    Allows an effective and comfortable use in fiber installation work
    Meets the IP65 standard
    Protection against humidity, and environmental inclemency.
    Fast and reliable joints

    Applications

    • Data network.
    • Perfect for FTTH networks, data center, security system, network repair etc.
    • Telecommunications Networks
    • Local Networks (LAN).

    Features:

    • Closed structure.
    • Material: PC + ABS, IP65 protection level.
    • Accommodation for the power cable and the connection cable, fiber division, splice, fixing, storage, distribution, etc ... all in one.
    • The hoses, tabs and network cables all have their own housing, allowing easy distribution.
    • The distribution panel can be folded up, facilitating maintenance and installation.
    • For use both outdoors and indoors
    • The box can be installed on the wall or on the mast,

    The insulation resistance between the grounding device and the metal parts of the box is less than 2 x 10 exp 4 MΩ / 500V (DC); IR≥2x10exp4MΩ / 500V
    The resistance of voltage between the device of connection to earth, the box and its metallic parts is not inferior to 3000 V (CC) / min, without punctures neither explosions; U≥3000V

    Does not include adapters, pigtail or splitter

     

    Specifications

     

     

    GFS-24E

    Insertion loss:

    <=0.2dB

    UPC return loss:

     >=50dB

    APC return loss:

    >=60dB

    Max Capacity

    Splitter 24

    Splice 24

    Environmental requirement

    Working temperature:

    -40º to +85º

    Relative humidity:

    <= 85% (+30ºC)

    Atmospheric pressure:

    70KPa~106Kpa

    Size

    250*340*110

    Installation Size

    155*180